Mitel Deutschland GmbH 68635RFP36U-01 用户手册

下载
页码 383
 
OM Management Portal (OMP) 
 
123 
RFP software update 
• 
Mode: RFP update mode. Options are “One by one” (each RFP is updated separately) or “All at once” 
(all RFPs are updated in one operation). 
• 
Time-controlled: Indicates whether the start of the RFP update is time-controlled. 
• 
Time of day: Specifies the time for time-controlled RFP updates.  
Note:  Updates triggers can be controlled through update intervals 
(DHCP, config files) or manually triggered via the 
Update button. 
 The “General” tab contains two additional buttons (aside from default buttons): 
• 
Update: Requests an immediate update of RFP software. 
• 
Restart: Requests an OMM restart. 
6.5.1.2 DECT settings 
For a description of the parameters which can be set in the 
DECT tab, see the description of the System 
settings page of the OMM Web service (see section 5.4.1). The corresponding parameters are 
described in the 
DECT settings and Downloading new firmware to portable parts page sections, with 
the exceptions noted below.  
 
The following settings are only available in the OMP. 
• 
Regulatory domain: the OMP offers an additional regulatory domain selection 
(Radio 1910-1927MHz 250mW) for SIP-DECT operation in some South American countries. See 
section 3.32  for more information on this feature.  
• 
SARI: Specify the Secondary Access Rights Identifier (SARI) for the Dual Homing feature. DECT 
phones subscribe to the SARI (instead of the PARK) to ensure that user data is synchronized across 
all OMMs in the system. See section 7.16 for more information on this feature. You can click the 
Generate SARI button to generate the SARI from the system PARK code.