Mitel Deutschland GmbH 68635RFP36U-01 用户手册

下载
页码 383
 
Configuration and Administration 
 
235 
7.7  LOCAL DECT BASE STATION CONFIGURATION (OM 
CONFIGURATOR) 
As an alternative to DHCP configuration, you can use the OM Configurator tool to statically configure the 
DECT base stations individually. RFP settings configured through the OM Configurator tool are saved 
permanently in the internal flash memory of the RFP. The OM Configurator version must match the 
installed SIP-DECT software version to be used for the local configuration of RFPs. 
Please note: 
The OM Configurator requires the Java Runtime Environment version 1.7 or 
higher. 
Please note: 
An initial configuration of the RFPs 35/36/37 IP / RFP 43 WLAN via the OM 
Configurator tool requires a login and password. The default login and password is “omm” 
and “omm”. No login is required for the initial configuration of the previous RFP family 
(RFPs 32/34 / RFP 42 WLAN. If the RFP is configured by the OMM later on, the OMM 
also sets the configuration password. You must enter the OMM’s full access user and 
password in the OM Configurator tool then.  
At start-up of the OM Configurator displays a table with configuration data for all RFPs. The task bar on 
the right side shows permitted actions. The Info console in the lower part of the window shows 
information and errors as they occur during OM Configurator operation 
 
 
7.7.1  SELECTING THE NETWORK INTERFACE 
You can select the network interface of the computer used by the OM Configurator via the 
General -> 
Options menu.  The selected interface is shown on the status line of the program.