7.26 DEVICE PLACEMENT  
The OM Locating application uses small graphic maps for visualization of DECT base station placement. 
From SIP-DECT release 3.1 on, these graphics can be created with the OMP in 
Planning Mode
7.26.1 “PLACEMENT” VIEW 
By using the mouse with drag and drop, you can move RFP icons to their correct mounting position on 
the loaded background image. Note that you must provide background images first (see also /27/). 
A DECT base station is drawn as green circle with its ID number inside. 
Background images can be loaded into the application on the 
Image Management panel (see section 
The assignment of devices to the currently active image must be done on the 
DECT base stations 
page. 
7.26.1.1  Functionality of the “Placement” View 
• 
Left mouse click selects/deselects the DECT base station the mouse is pointing to. A selected device 
is shown with thicker border. 
• 
Drag and drop functionality: a device can be moved while the left mouse button is pressed and hold. 
• 
If left mouse button is hold and no device is selected, the complete view content gets moved. 
• 
By turning the mouse wheel the view gets scaled up or down depending from the direction of turning. 
• 
By pressing the right mouse button a pop-up menu is displayed: 
Move selected RFPs: All selected devices (drawn with a thick border) will be moved to the current 
position of the mouse pointer. Distances between the devices are not changed as long as all 
devices can be drawn inside the background image. Moving devices to the area outside the upper 
or left border of the image is not possible. 
Reset selection: The selection is canceled for all currently selected devices. 
Remove selected device(s): Selected devices are removed from the current image after 
confirmation in a dialog box. Those devices can be assigned to an image again via the 
DECT base 
stations menu (see also section 7.26.2). 
If no devices are selected but the mouse is pointing to a device, that device is removed from the 
image without further inquiry. 
Reset view: The view is redrawn in its original appearance. Any translation and scaling applied to 
the view is cancelled. 
 
7.26.1.2  Activation of the “Placement View” 
The 
Placement view can be activated by: 
• 
Selecting the 
Placement view menu entry. The currently loaded image with its assigned devices is 
displayed. If no image is currently loaded, the view is empty.