Geonautics International Pte Ltd 30-0710 用户手册
TAG-T3 Wombat – User Guide, 1.0.7
Commands
4.3.4 Voltage
Set the trigger levels for voltage rises and voltage drops. The duration
of the trigger is set by the duration time of the Motion (Configuration)
command. See page 22.
$GO0,,VLT[,<low>][,<high>]
$GOA,<Unit_Id>,VLT,<low>,<high>
Voltage Command
Description
low
Lower voltage trigger level expressed as volts*10
high
Upper voltage trigger level expressed as volts*10
Table 7, Voltage Command
Default:
$GO0,,VLT,0,135
Example:
$GO0,,VLT,20,120
Returns:
$GOA,<Unit_Id>,VLT,20,120
A voltage setting of 135 is interpreted as 13.5 volts.
When setting the high limit to sense the alternator induced voltage
rise, use the Parameter, page 42, or Debug (Last), page 44, command
to establish the voltage when the engine is running and then set the
high value to a voltage slightly under that voltage (0.3 volts lower is
normally sufficient).