Zebra Technologies Corporation FX7400 用户手册

下载
页码 116
B - 4
FX Series RFID Readers Integrator Guide
d.
Click 
Start Update
 to start the update. The reader indicates that it is going to shutdown.
e.
The green LED on the reader flashes during the update. The reader application software first downloads 
osupFX.exe
FlashUpdateUtility.dll
, and 
Response.txt
 files, starts running 
Osupdate
, and shuts down. 
Osupdate
 then downloads all the files specified in the 
Response.txt
 file into RAM, and if successful writes 
the files to Flash. If the ftp is not successful, no files are written to Flash. 
f.
The update can take up to 15 minutes. Do not remove power to the reader or reboot the reader during the 
update.
g.
The reader reboots when the update completes.
h.
If the reader is set up with a static IP address, it restores the static IP address and reboots again.
i.
The reader may reboot a third time if the FPGA version has changed. 
10.
Log onto the web console, access the 
Version Control
 screen, and verify the new upgrade version is running.
NOTE
During the FPGA update, all the LEDs turn off for about 90 seconds. 
If there is a power outage during the upgrade, when the power comes back on, the reader Monitor 
program retrieves all the files using the TFTP server and saves them to Flash.