Zebra Technologies Corporation FX7400 用户手册
B - 4
FX Series RFID Readers Integrator Guide
d.
Click
Start Update
to start the update. The reader indicates that it is going to shutdown.
e.
The green LED on the reader flashes during the update. The reader application software first downloads
osupFX.exe
,
FlashUpdateUtility.dll
, and
Response.txt
files, starts running
Osupdate
, and shuts down.
Osupdate
then downloads all the files specified in the
Response.txt
file into RAM, and if successful writes
the files to Flash. If the ftp is not successful, no files are written to Flash.
f.
The update can take up to 15 minutes. Do not remove power to the reader or reboot the reader during the
update.
update.
g.
The reader reboots when the update completes.
h.
If the reader is set up with a static IP address, it restores the static IP address and reboots again.
i.
The reader may reboot a third time if the FPGA version has changed.
10.
Log onto the web console, access the
Version Control
screen, and verify the new upgrade version is running.
NOTE
During the FPGA update, all the LEDs turn off for about 90 seconds.
If there is a power outage during the upgrade, when the power comes back on, the reader Monitor
program retrieves all the files using the TFTP server and saves them to Flash.