Advanced Card Systems Limited ACR1222LD1 用户手册

下载
页码 77
 
 
ACR122L-USB-ACS
Command 
 
Class 
INS 
P1 
P2 
Lc 
LCD Contrast 
Control 
0xFF 
0x00 
0x6C 
Contrast Control 
0x00 
 
P2: Contrast Control 
The  value  range  is  between  0x00  to  0x0F.  It  is  as  large  as  brighten  on  contrast.  Otherwise  the 
contrast will been darken. 
 
Data Out: SW1 SW2. 
Table 13.0B: Status Code 
Results 
 
SW1 
SW2 
Meaning 
Success 
90 
00 
The operation is completed successfully. 
Error 
63 
00 
The operation is failed.  
 
6.3.13. 
Pseudo APDU for LCD Backlight Control 
This APDU is used to Control the LCD Backlight 
 
Table 14.0A: LCD Backlight Control Command Format (5 Bytes) 
Command 
 
Class 
INS 
P1 
P2 
Lc 
LCD Backlight 
Control 
0xFF 
0x00 
0x64 
Backlight 
Control 
0x00 
 
P2: Backlight Control 
Table 14.0B: Backlight Control Format (1 Byte) 
CMD 
Description 
0x00 
LCD Backlight Off 
0xFF 
LCD Backlight On 
 
 
Data Out: SW1 SW2. 
Table 14.0C: Status Code 
Results 
 
SW1 
SW2 
Meaning 
Success 
90 
00 
The operation is completed successfully. 
Error 
 
63 
00 
The operation is failed.