Escape APDU for LEDs Control 
This APDU is used to control 4 LEDs 
 
Table 4.0A: Clear LCD Command Format (5 Bytes) 
Command 
 
Class 
INS 
P1 
P2 
Lc 
LED Control 
0xFF 
0x00 
0x41 
bLEDsState 
0x00 
 
P2: bLEDsState 
LED_0, LED_1, LED_2 and LED_3 Control Format (1 Byte) 
CMD 
Item 
Description 
Bit 0 
LED_0 State 
1 = On; 0 = Off 
Bit 1 
LED_1 State 
1 = On; 0 = Off 
Bit 2 
LED_2 State 
1 = On; 0 = Off 
Bit 3 
LED_3 State 
1 = On; 0 = Off 
Bits 4 – 7 
Reserved 
 
 
Data Out: SW1 SW2. 
Table 4.0B: Status Code 
Results 
 
SW1 
SW2 
Meaning 
Success 
90 
00 
The operation is completed successfully. 
Error 
 
63 
00 
The operation is failed.