Corning Optical Communication Wireless MAVELTE700L 用户手册

下载
页码 91
Overview 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
8
 
 
1.4 
System Monitoring and Management 
The  MobileAccessVE  system  (Master  VCU,  Slave  VCUs,  and  VAPs)  is  centrally  managed  via  a 
single Web connection to the Master VCU. The basic screen in the GUI is the Config tab, which 
enables  the  user  to  view  the  system  topology  and  setup  parameters,  Control  Units,  and  all 
Access Pods connected to the Control Units. 
Note: When locally connecting to a specific Slave VCU, only the VAPs connected to this VCU can 
be  monitored.  However,  when  connected  to  the  Master,  the  entire  deployment  can  be 
monitored.  
 
1.4.1 
Integration with an External Fault Management System 
The  MobileAccessVE  system can be seamlessly integrated  into any existing  Fault Management 
(FM)  system  that  supports  SNMP  events.  The  Master  VCU  generates  a  SNMP  event  for  each 
relevant system alarm and forwards  this trap  to the  pre-configured  IP address  of the external 
Fault Management system.