VCU Monitoring and Configuration 
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual 
62
 
The following table provides a description of the RF parameters displayed in the Service RF tabs. 
Parameter 
Description 
Type 
Set (read only) according to unit type (LTE) 
Service Mode 
Provides the service options: MIMO/SISO/Off. The selected option 
determines the displayed RF parameters. 
DL CF* 
Set (read only) center frequency (from BTS) according to LTE 700 MHz 
range - Band 13 (upper Block). The CF is the same for both UL and DL 
signals. 
UL System Gain 
Used for adjusting the UL system gain. Range: -15 dB to +5 dB 
Max Exp Pin* 
Maximum expected input power from the BTS. Used for adjustment 
procedure. Range: 0-33 dBm. User defined. 
Channel 1 / 
Channel 2 Pin 
Actual measured Pin (read only). In SISO mode only Channel 1 Pin is 
relevant. 