Intel P4304BTSSFCN 用户手册

下载
页码 20
Monthly Specification Update 
Enterprise Platforms and Services Marketing 
 
Summary Tables of Changes 
The following tables provide an overview of known errata and known document changes that 
apply to the specified Intel
®
 Server Products. The tables use the following notations: 
Doc 
Intel
®
 intends to update the appropriate documentation in a future revision. 
Fix 
Intel
®
 intends to correct this erratum. 
Fixed 
This erratum has been corrected. 
No Fix 
There are no plans to correct this erratum. 
Shaded 
This item is new or has been modified from the previous specification update. 
Table 1. Errata Summary 
No. 
Plans 
Description of Errata 
Fixed 
Bios setting is locked after running ‘syscfg/bldfs’ to load Bios default setting. 
Fixed 
Admin Password is cleared after loading user defaults. 
Fixed 
By using LSI* SCSI storage card 20320 can’t enter into Microsoft Windows 2008* R2. 
Fixed 
Intelligent Platform Management Bus (IPMB) functions on devices connected to IPMB connector might 
not be available on Intel
®
 Server Board S1200BTL. 
Fixed 
Unable to install SLES* 11 Service Package 1 to iSCSi drive from onboard Intel
®
 82579 network card. 
No Fix  Node Manager does not work with Intel
®
 Core™ Processor i3-2100 series
 
or Intel
®
 Pentium
®
 
Processor. 
Fixed 
Intel
®
 Integrated RAID Module SRMS2LL040 does not work. 
Fixed 
Memory Mapped I/O above 4 GB option can’t map 64bit addresses. 
Fixed 
Windows 2008* R2 can’t be installed properly or the OS will hang with NIC ROM disabled in BIOS. 
10 
Fixed 
The SGPIO cable is not compatible with Intel
®
 SAS Entry Raid Module AXX4SASMOD, Intel
®
 
Integrated RAID Module SRMS2AF040 and Intel
®
 Integrated RAID Module SRMS2LL040. 
11 
Not 
Fix 
When EULOT 6 is enabled, the system can’t boot up by press power button once. 
12 
Fixed 
The value of SMI BIOS type 17 is not correct. 
13 
Fixed 
BMC user SOL payload enable/disable status can’t be saved across BMC reset. 
14 
Fixed 
SOL activation is failed when Console Redirection is disabled in BIOS Setup. 
15 
Fixed 
The 4th HDD cage interferes with the right side rack handle screws on then Intel
®
 R1304BTLSHBN. 
16 
Fixed 
Microsoft* Windows SBS 2011 Essential doesn’t recognize ESRT2 driver during installation 
17 
Fixed 
System may hang about 20 seconds during system rebooting 
18 
Fix 
Some Function Keys does not work through SOL session 
19 
Fixed 
Keyboard does not work under EFI if USB flash disk is inserted/removed when enabled TXT in BIOS 
20 
Fixed 
When using Hardware RAID controller,  pressing “Ctrl+G” can not enter RAID configuration utility 
21 
Fixed 
The RPM of three fans on Intel
®
 Server System R1304BTLSHBN drops to 0 sometimes after AC cycle 
22 
Fixed 
PCT reports "Processor Does Not Support Brand ID" 
23 
Fixed 
The SEL is keep reporting when RAID is rebuilding on Intel
®
 Server System R1304BTLSHBN 
24 
Fixed 
The system can not detect more than 8 USB devices 
25 
Fix 
USB Keyboard mouse cannot wakeup the system from the Standby mode