Modem On/Off Control 
The modem on/off input line (HOSTPWR_ON) is an active high input 
signal and is fitted with a 33Ω series resistor for input protection. 
Internally it is passively pulled low (after the series resistor) to ground 
and is asserted with a high input signal.  
The Boomer-III modem is fitted with a Real Time Clock that third 
party applications may utilise to wake-up the modem at a pre-
programmed alarm time. This facility may be utilised to further reduce 
current consumption in battery powered applications, but note that the 
modem may need to re-register on the network after wake-up 
The electrical interface specification and equivalent circuit is as 
follows: 
Modem On/Off Control Equivalent Circuit 
 
Modem On/Off Control Electrical Characteristics 
Parameter Range  Low High 
Input Voltage 
0-3V 
OR 
0-5V 
1.0 V (max) 
2.5 V (min) 
Input Current 
 
20 µA (max) 
100 µA (max)