Grounding
Site Installation
Figure 1‐56: Waterproofing an external connection
1.2.9 Grounding
All RADWIN products should be grounded during operation. In addition:
•
All units should be grounded by a wire with diameter of at least 10 AWG.
Units must be properly grounded to a Protective Ground in accordance with the Local
Electrical Regulations
Electrical Regulations
•
Rack‐mounted equipment should be mounted only in grounded racks and cabinets.
Further, you should ‐
•
Always make the ground connection first and disconnect it last
•
Never connect telecommunication cables to ungrounded equipment
•
Ensure that all other cables are disconnected before disconnecting the ground
TBS
. Ground it using 10 AWG wire.