Radwin Ltd. BFJET5X 用户手册
RADWIN 5000 Installation Guide
Release 4.9.30
B‐1
Appendix B: Wiring
Specifications
Specifications
B.1 Scope of this Appendix
This appendix shows wiring specifications for the HBS and HSU.
B.1 Radio unit‐PoE Cable (HBS and HSU)
The radio unit‐PoE cable is shielded/outdoor class CAT‐5e, 4 twisted‐pair 24 AWG terminated
with RJ‐45 connectors on both ends. A cable gland on the radio unit side provides hermetic
sealing.
with RJ‐45 connectors on both ends. A cable gland on the radio unit side provides hermetic
sealing.
The following table shows the connector pinout:
Table B‐1: Radio unit‐PoE RJ‐45 Connector Pinout
Function
Color
PoE
ODU
Rx N
White/Green
1
1
Rx T
Green
2
2
Tx T
White/Orange
3
3
Tx N
Orange
6
6
Power (+)
Blue
4
4
Power (+)
White/Blue
5
5
Power ()
White/Brown
7
7
Power ()
Brown
8
8