Radwin Ltd. BSA5XSDR 用户手册

下载
页码 5
Maximum Output Power 
 
5725 
– 5850 MHz band - FCC/IC 
The  maximum  output  power  can  be  set  as  follows,  when  operating  in  the  5.8  GHz  band, 
under FCC and IC regulations. The power values are for PtP systems and PtMP systems. For 
PtMP systems the total EIRP is limited to 36 dBm. Therefore the output power of the system 
will be reduced to comply with 36 dBm EIRP.  
 
   
RADWIN 2000 JET (PtP) 
RADWIN 5000 JET (PtMP) 
  5 MHz: 29.5 dBm 
10 MHz: 29.5 dBm 
20 MHz: 29.6 dBm 
40 MHz: 29.5 dBm 
  5 MHz: 15.0 dBm 
10 MHz: 15.0 dBm 
20 MHz: 15.1 dBm 
40 MHz: 15.0 dBm 
 
 
 
5250 
– 5350 MHz band – FCC/IC 
The maximum output power can be set as follows, when operating in the 5.3 GHz band. The 
total EIRP limit is 30 dBm.  
 
10 MHz: 5.95 dBm    
20 MHz: 9.34 dBm  
40 MHz: 9.30 dBm 
 
 
 
5470 
– 5725 MHz band – FCC/IC
2
 
The maximum output power can be set as follows, when operating in the 5.3 GHz band. The 
total EIRP limit is 30 dBm. 
 
10 MHz: 6.05 dBm  
20 MHz: 9.35 dBm 
40 MHz: 9.49 dBm  
 
 
Radiation Exposure Evaluation 
 
RADWIN  2000  JET  systems  -  the  calculated  recommended  safe  distance  at  density  of 
1mW/cm
is 76cm. 
 
RADWIN 5000 JET systems - the minimum separation distance is 20cm 
 
 
 
 
 
 
 
 
2    
Under IC regulations the 5600-5650 MHz band is excluded from operation 
 
RADWIN 2000 JET, RADWIN 5000 JET Reference Guide
 
2