3.1 Scope of this Chapter
This chapter describes various safety practices.
3.1.1 Preventing Overexposure to RF Energy
To protect against overexposure to RF energy, install the radio units so as to provide and 
maintain minimal separation distances from all persons.
When the system is operational, avoid standing directly in front of the antenna. Strong RF 
fields are present when the transmitter is on. The radio unit must not be deployed in a 
location where it is possible for people to stand or walk inadvertently in front of the antenna.
3.1.2 Grounding
All RADWIN products should be grounded during operation. In addition:
All ODUs should be grounded by a wire with diameter of at least 10 AWG.
The ground lug on an IDU‐H should be connected to the protective earth at all times, by 
a wire with a diameter of 18 AWG or wider. 
Rack‐mounted equipment should be mounted only in grounded racks and cabinets.
Further, you should ‐
Always make the ground connection first and disconnect it last
Never connect telecommunication cables to ungrounded equipment
Ensure that all other cables are disconnected before disconnecting the ground
3.1.3 Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All 
RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of 