WinLink 1000 Installation and Operation Manual 
Chapter 4  Operation 
ƒ 
TDM Service - Alarm. (added in 1.1.3) 
ƒ 
TDM Service - Normal. (added in 1.1.3) 
Π
To change link configuration parameters: 
1.  In the Main menu, click Configure Link. 
The Configure Link wizard appears. See 
Chapter 3
 for 
configuration details. 
2.  Click Next. 
3.  Continue through the configuration wizard and define the Link 
name and ID, Channel, Rate and Services. 
4.  Once you finish changing configuration parameters, click Finish. 
The system takes a few seconds to activate the link with the new 
configuration. 
Resetting WinLink 1000 
Note
 
In order to maintain the communication link, always reset the remote 
WinLink 1000 first
.
 
 
Π
To reset WinLink 1000: 
1.  Click on maintenance, select the remote WinLink 1000 to reset. 
2.  Click on maintenance, select the local WinLink 1000 to reset. 
Saving WinLink 1000 Configuration in a File 
WinLink 1000 management software allows you to save configuration 
parameters of the local and remote units on the management station 
as an INI file. Each site is saved in a separate INI file. 
Π
To save configuration in a file: 
1.  From the Configuration menu, select the site to backup. 
The Configuration dialog box opens (see 
Figure 3-9
). 
2.  Click Backup. 
3.  In the Save As dialog box, indicate in which folder and under what 
name configuration file is to be saved, and click Save. 
 
Managing WinLink 1000 