Radwin Ltd. AMWL1240 用户手册

下载
页码 98
WinLink 1000 Installation and Operation Manual 
Chapter 
 
5  Diagnostics and Troubleshooting 
 PM 
Frequently Asked Questions 
5-9 
Q: In BAND C, can you add the frequency of 5.735 to the manual 
selection in order to increase the number of 20 MHz channels to six? 
A: Currently the system provides 5 fixed channels. Yet, the manual 
frequency setting provides more flexibility of spectrum selection, 
including 5.735 MHz. 
Q: Do we need to add external arrestors on WinLink 1000  cables? 
A: The WinLink 1000 ODU includes arrestors and lightning protection. 
Therefore there is no need to add additional arrestors.  
Q: What is the sensitivity for each rate of the WinLink 1000?  
A: The sensitivities are:  
ƒ
 
Rate 12 Mbps     -84 dB 
ƒ
 
Rate 18 Mbps     -81 dB 
ƒ
 
Rate 36 Mbps     -74 dB 
ƒ
 
Rate 48 Mbps     -68 dB 
Q: Does WinLink 1000  use DSSS technique? 
A: No, WinLink 1000  uses the advanced OFDM technique.  
Management 
Q: Can we mange WinLink 1000  using SNMP other then the supplied 
management software that comes with the units? 
A: Yes. The WinLink 1000  is SNMP based, when using other SNMP 
software, and after implementing RADWin MIB’s, the WinLink 1000  can 
be managed.