Radwin Ltd. AMWL1530 用户手册

下载
页码 98
WinLink 1000 Installation and Operation Manual  
Quick Start Guide 
 
Operating WinLink 1000 
Troubleshooting 
If the WinLink 1000 is not operational, determine the cause and solution 
from the table below.  
 
Led Status 
Remedy 
PWR  
Off 
For the IDU-E, check that AC adapter is connected 
to the IDU and the AC power outlet. 
IDU  
Orange 
Check that the IDU/ODU cable is properly wired 
and connected. 
ODU  
Red 
Check that the IDU/ODU cable is properly wired 
and connected. 
Orange 
Complete the installation procedure from the 
management software. 
AIR I/F  
Red 
Check the ODU Antenna alignment. Check that 
the radio configuration of both site A and site B 
units are the same (channel and SSID). 
Off 
Check the TDM service configuration in the NMS. 
Orange 
Check that the system is not in loopback mode. 
Check the site B IDU ports and cables and site B 
external equipment. 
SVC.  
Red 
Check the site A IDU ports, cables and external 
equipment.