Chapter 3  Configuration 
WinLink 1000 Installation and Operation Manual 
ODU Bridge Mode 
This parameter controls the ODU mode with two optional values,  
• 
Bridge Mode (default) (Figure 3-17 ). In "bridge" mode the ODU 
performs both learning and aging, the aging time of the ODU if 
fixed. 
• 
Hub Mode - in "hub" mode the ODU transparently forward the all 
the packets over the wireless link.  
 
Changing these parameters requires system reset. 
Note
 
IDU Aging time 
This parameter controls the IDU (E and C) aging time.  
The IDU has 2K MAC address learning table. The aging time parameter 
controls the time each MAC address is dropped from the table. Default 
value is 300 (sec).  
 
Change to these parameters is effective immediately. 
Note
 
 
Each side of the link can be configured separately. 
Note
 
The following list detail common configurations, both sides are 
configured with the same values. 
• 
Standard (Default) Configuration for Ethernet Applications 
IDU-E or IDU-C aging is set to 300 sec (ODU is set to Bridge mode, 
Figure-1). 
• 
Fast aging mode
 (for rapid network topology changes) 
IDU-E or IDU-C aging is set to 1 seconds, ODU is set to Hub mode 
(Figure 3-18). 
3-18 Bridge 
Configuration