WinLink 1000 
  TDM Clock Configuration 
 
Behavior in fault configuration 
D-3 
Example 1 
Site A clocks: E1-1 IN and E1-2 IN differ, and all trunks are in normal 
condition, WINLink 1000 shall use trunk 1 for the timing and the 
second trunk shall experience pattern slips (the rate of the pattern 
slips is dependent on the ratio between the different clocks) 
Example 2 
Trunk 1 is disconnected and trunk 2 is in normal condition. 
WINLink 1000 shall select trunk 2 for clock timing. Since trunk 1 is 
disconnected it uses an internal clock as an input clock. The OUT clock 
of both trunks is the re-generated clock IN 2, and therefore  
WINLink 1000 shall display error blocks on clock 1 (represents the 
clock difference between the internal clock and the IN 2 clock).