Radwin Ltd. RW2049 用户手册

下载
页码 211
Protection against Lightning
 Chapter 3
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
3-2
also lays down the size of grounding conductors and connection 
requirements for grounding electrodes.
The RADWIN 1000/2000/5000 ODU must be grounded to a Protec-
tive Earth as described in appendix 
and in accordance with the 
Local Electrical Regulations.
• The earth lug on the IDU-C and IDU-E should be connected to the 
protective earth at all times, by a wire with a diameter of 18 AWG 
or wider. Rack-mounted equipment should be mounted only in 
earthed racks and cabinets.
Further, you should -
• Always make the ground connection first and disconnect it last
• Never connect telecommunication cables to ungrounded equipment
• Ensure that all other cables are disconnected before disconnecting 
the ground
More detailed guidelines are supplied in appendix 
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user 
requirements. All of RADWIN outdoor units are designed with surge limiting 
circuits to minimize the risk of damage due to lightning strikes. RADWIN 
recommends the use of additional surge arrestor devices to protect the 
equipment from nearby lightning strikes.
 for detailed installation instructions of lightning protection 
devices.
General
• It is recommended that installation of the outdoor unit be contracted 
to a professional installer.
• Before working on equipment connected to power lines or telecom-
munication lines, you should remove jewelry or any other metallic 
object that may come into contact with energized parts.
• Use extreme care when installing antennas near power lines.
• Use extreme care when working at heights.
• When using an AC power source for RADWIN 1000/2000/5000 
always use the AC power adapter supplied by RADWIN.
• Use the right tools. In addition to standard tools required for any 
kind of ODU or antenna installation, RADWIN 1000/2000/5000 
requires additional specific tools detailed on 
 below.
Package Contents
The RADWIN 1000/2000/5000 packages include the following items:
ODU Package Contents
The ODU package contains: