Radwin Ltd. RW2058 用户手册

下载
页码 211
RADWIN Manager Traps
 Chapter 7
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
7-11
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events, 
displayed in the Wvents Log.
Table 7-5: RADWIN Manager Trap Messages
Trap Message
Severity
Remarks
Error loading trap catcher. Port 162 is already in use.
Warning
NMS will not catch any 
traps from target, some 
other application has 
grabbed this port
Device unreachable!
Error
Check connectivity to target
Connected to <site_name>
Information
<site_name> Site will be reset.
Information
Restore Factory Default Settings in process on Site 
<site_name>
Information
Factory Settings: The process was not finished due to  
connection issues.
Warning
Factory setting failed due to 
connectivity problem to tar-
get 
Reset: The process was not finished due to connec-
tion issues.
Warning
Factory setting failed due to 
connectivity problem to tar-
get - Target will not be 
reset
Cannot Write to Monitor file. There is not enough 
space on the disk.
Warning
Free some space on disk 
and retry
Windows Error: <error_ID>. Cannot Write to Monitor 
file.
Warning
Operating System error
TDM Counters were cleared for both sides
Information
Identical IP addresses at <local_site_name> and 
<remote_site_name>
Warning
Set up a different IP to each 
site 
The Product is not identified at the 
<local_site_name> site.
Warning
NMS is incompatible with 
the target release
The Product is not identified at the 
<remote_site_name> site.
Warning
The Product is not identified at both sites.
Warning
Product Not Identified!
Warning
The Manager identified a newer ODU release at the 
<remote_site_name> site.
Warning
ODU release is newer than 
NMS release. Wizards are 
not available. NMS will be 
used just for monitoring. 
Upgrade the NMS. (You will 
get this message as a pop 
up)