Radwin Ltd. RW2058U 用户手册

下载
页码 211
MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
F-6
winlink1000OduAdmHostsPort
1.3.6.1.4.1.4458.1000.1.1.12.1.3
Integer
RW UDP port of the trap destination. A change is 
effective immediately. 
winlink1000OduBuzzerAdminState
1.3.6.1.4.1.4458.1000.1.1.13
Integer
RW This parameter controls the activation of the 
buzzer while the unit is in install mode. A change is 
effective immediately. The valid values are: 
disabled (0) enabled (1). 
winlink1000OduProductId
1.3.6.1.4.1.4458.1000.1.1.14
DisplayString
RO
This parameter is reserved for the Manager 
application provided with the product. 
winlink1000OduReadCommunity
1.3.6.1.4.1.4458.1000.1.1.15
DisplayString
RW Read Community String. This parameter always 
returns ***** when retrieving its value. It is used by 
the Manager application to change the Read 
Community String. The SNMP agent accepts only 
encrypted values. 
winlink1000OduReadWriteCommunity
1.3.6.1.4.1.4458.1000.1.1.16
DisplayString
RW Read/Write Community String. This parameter 
always returns ***** when retrieving its value. It is 
used by the Manager application to change the 
Read/Write Community String. The SNMP agent 
accepts only encrypted values. 
winlink1000OduTrapCommunity
1.3.6.1.4.1.4458.1000.1.1.17
DisplayString
RW Trap Community String. This parameter is used by 
the Manager application to change the Trap 
Community String. The SNMP agent accepts only 
encrypted values. 
winlink1000OduAdmSnmpAgentVersion
1.3.6.1.4.1.4458.1000.1.1.18
Integer
RO
Major version of the SNMP agent. 
winlink1000OduAdmRemoteSiteName
1.3.6.1.4.1.4458.1000.1.1.19
DisplayString
RO
Remote site name. Returns the same value as 
sysLocation parameter of the remote site. 
winlink1000OduAdmSnmpAgentMinorVe
rsion
1.3.6.1.4.1.4458.1000.1.1.20
Integer
RO
Minor version of the SNMP agent. 
winlink1000OduAdmLinkPassword
1.3.6.1.4.1.4458.1000.1.1.21
DisplayString
RW Link Password. This parameter always returns 
***** when retrieving its value. It is used by the 
Manager application to change the Link Password. 
The SNMP agent accepts only encrypted values. 
winlink1000OduAdmSiteLinkPassword
1.3.6.1.4.1.4458.1000.1.1.22
DisplayString
RW Site Link Password. This parameter always returns 
***** when retrieving its value. It is used by the 
Manager application to change the Link Password 
of the site. The SNMP agent accepts only 
encrypted values. 
winlink1000OduAdmDefaultPassword
1.3.6.1.4.1.4458.1000.1.1.23
Integer
RO
This parameter indicates if the current Link 
Password is the default password. 
winlink1000OduAdmConnectionType
1.3.6.1.4.1.4458.1000.1.1.24
Integer
RO
This parameter indicates if the Manager 
application is connected to the local ODU or to the 
remote ODU over the air. A value of 'unknown' 
indicates community string mismatch. 
winlink1000OduAdmBackToFactorySetti
ngsCmd
1.3.6.1.4.1.4458.1000.1.1.25
Integer
RW Back to factory settings Command. A change is 
effective after reset. The read value is always 0. 
winlink1000OduAdmIpParamsCnfg
1.3.6.1.4.1.4458.1000.1.1.26
DisplayString
RW ODU IP address Configuration. The format is: 
<IP_Address>|<Subnet_Mask>|<Default_Gatewa
y>| 
winlink1000OduAdmVlanID
1.3.6.1.4.1.4458.1000.1.1.27
Integer
RW VLAN ID. Valid values are 1 to 4094. Initial value is 
0 meaning VLAN unaware. 
winlink1000OduAdmVlanPriority
1.3.6.1.4.1.4458.1000.1.1.28
Integer
RW VLAN Priority. 0 is lowest priority 7 is highest 
priority. 
winlink1000OduAdmSN
1.3.6.1.4.1.4458.1000.1.1.29
DisplayString
RO
IDU Serial Number 
winlink1000OduSrvMode
1.3.6.1.4.1.4458.1000.1.2.1
Integer
RW System mode. The only value that can be set is 
installMode; normalMode reserved to the Manager 
application provided with the product. A change is 
effective after link re-synchronization. 
Table F-2: Private MIB Parameters (Sheet 2 of 14)
Name
OID
Type
Access
Description