Chapter 2  Initial Setup 
AirMux-104 Installation and Operation Manual 
2-6 
Performing Initial Setup of AirMux-104
 
 
Configuring Service Parameters 
In the Service Parameters dialog box you can configure E1 and Ethernet 
parameters. In addition, you can assign IP addresses of the local and remote 
AirMux-104 units. 
 
To configure E1 and Ethernet parameters: 
1.  In the General Parameters dialog box, perform the following steps: 
 
Select the Ethernet Only check box, if you intend to transmit Ethernet data 
only. 
 
Select E1 service type, framed or unframed.  
 
Framed E1 – assign timeslots to carry data.  
You can assign all timeslots by clicking Select All, clear you selection by 
clicking Clear All.  
Timeslot 0 is reserved for framing information and cannot be selected to 
carry user’s data. 
 
Unframed E1 – all timeslots are assigned to carry data automatically. 
 
When you assign timeslots to carry E1 data, AirMux-104 automatically calculates the 
bandwidth remained for the Ethernet traffic. This value is displayed in the Data Rate 
field at the right-hand corner of the Service Parameters dialog box (see 
 
 
Enable CRC-4 bit generation, if required. 
 
Click Next, if you do not intend to configure IP parameters of the 
AirMux-104 units. 
 
Figure 2-5.  Service Parameters Dialog Box 
Note