Radwin Ltd. WL1000F49 用户手册

下载
页码 97
Quick Start Guide 
WinLink 1000 Installation and Operation Manual 
Installing WinLink 1000 Units 
 
• 
Drill (for wall mounting only) 
• 
IDU and ODU grounding cable 
• 
13 mm or 1/2″ socket spanner 
• 
ODU to IDU cable if not ordered (Outdoor class, CAT-5e, 4 twisted 
pairs) 
• 
Cable ties 
• 
Laptop running Windows 2000 or Windows XP 
Before the installation 
1.  Install the WinLink 1000 software on the laptop. 
2.  Verify that all equipment and tools are available. 
Performing Installation 
Î
 
To install the ODU: 
1.  At site A, route the ODU cable from the ODU location (on the roof) to 
the IDU location (inside the building). The maximum length is 100m. 
2.  Mount the ODU unit to the mast or wall, using the mounting kit. 
3.  Connect the RJ-45 connectors to both ends of the cable, use the 
pinout table and diagram below: 
 
 IDU 
RJ-45 
Wire 
Color 
Function 
ODU 
RJ-45 
1 White/Green 
Ethernet 
(RxN) 
 
 
Twisted  
2 Green Ethernet 
(RxT) 
 
3 White/Orange 
Ethernet 
(TxT) 
 
 
Twisted 
Blue 
Power (+) 
4  
White\Blue 
Power (+) 
5  
 
Twisted 
6 Orange 
Ethernet 
(TxN) 
 
7 White/Brown 
Power (−) 
7  
 
Twisted 
8 Brown Power (−) 
8  
 
4.  Secure the ODU and ground cables to the mast or brackets using 
cable ties. 
5.  Repeat the procedure at site B.