NOTE: If two gate sensors are set up within 8 m of one another, the respective
antennas must be synchronized. To facilitate this, a cable (2x2x0,22 mm
2
shielded and paired, such as Unitronic (LiYCY (TP) Æ ca. 7,0 mm) needs to be in-
stalled. 
Data transfer
If data stored from the gate sensor process needs to be analyzed the standard
and present interface of the scanner module can be used. In order to transfer the
data, a PC with the appropriate software is required. The data transfer is done
through an RS 232 /RS 485 interface. This requires a cable between the basis-
antenna and the respective PC to be installed prior to system delivery and instal-
lation. The PC requires a free COM port. With respect to the PC, the cable should
be connected to a LAN interface in direct proximity to the PC. The cable con-
nected to the basis-antenna is connected during installation. The cable 2x2x022
mm
2
 shielded and paired such, such as Unitronic (LiYCY (TP) Æ ca. 7,0 mm),
cannot be longer than 30 m and should be installed prior to system delivery and
installation. 
NOTE: When more than one gate sensor port is connected to a central PC each
basis antenna will require a free COM port.