OPISYS AVHR-5000N 用户手册

下载
页码 17
12 
All rights reserved 
AV
H
R
-500
0N
 
I.
Isolation  check mechanism 
II.
Oscillation check mechanism 
III. Sleep Mode mechanism 
IV. ALC(Auto Level Control) mechanism 
V.
RF Shut Down mechanism 
6. Safeguard features 
6.1  Summary
 
   This equipment have functions to protect as follows
6.2  Feature 
 
        6.2.1   Isolation check mechanism 
                - The booster automatically checks the isolation by increasing the 
                   DL path gain by 1dB when the power supply is switched on and/or  
                   the oscillation occurs. 
                  It works normally  when the isolation is over the maximum gain(48dB) 
                  plus 10dB, 58dB.  
 
        6.2.2   Oscillation check mechanism 
                - Anti-oscillation function is to protect Booster by D/L path off  
                  when oscillation in service. D/L shutdown by isolation check function 
                  when D/L path output power exceed oscillation limit value.  
            
        6.2.3   Sleep Mode mechanism 
                - When there is no U/L path Input signal, Booster shall be shut down  
                  after 30 seconds. 
                  Under the Sleep Mode condition, if U/L path input signal is above  
                  -92dBm, U/L path shall be turned on. 
 
        6.2.4   ALC(Auto Level Control) mechanism 
                - ALC function is always working to protect Booster. 
  
        6.2.5   RF Shut Down mechanism 
                - AMP is automatically shut down when the system output power  
                  exceeds the set point over five seconds.