1.2.3. Function
Page 4
IV. UL PATH Automatic Sleep Mode (continue )
• Automatic Turn OFF / if UL PATH < -92dBm
• Automatic Turn ON / if UL PATH > -90dBm
**BAND 12 & BAND 13 PATH gain limits are independently controlled
• Automatic Turn OFF / if UL PATH < -92dBm
• Automatic Turn ON / if UL PATH > -90dBm
**BAND 12 & BAND 13 PATH gain limits are independently controlled
V. Oscillation Auto Prevention
•
•
Degradation Protection: Detects potential performance degradation due to
the overload LTE feedback (over-heating) signals by Isolation Check & Gain
Configuration.
the overload LTE feedback (over-heating) signals by Isolation Check & Gain
Configuration.
•
Feedback Limits: Sets the operating range to exceeding high level Signals
from Donor Antenna (external antenna) of a signal booster to Service
Antenna (internal antenna)
from Donor Antenna (external antenna) of a signal booster to Service
Antenna (internal antenna)
BDA Gain < Antenna to Antenna Isolation – 15dB
If optimal isolation gain is not attained, PATH OFF shuts off automatically
**BAND 12 & BAND 13 Uplink PATH are independently controlled
If optimal isolation gain is not attained, PATH OFF shuts off automatically
**BAND 12 & BAND 13 Uplink PATH are independently controlled