Fiber Optic RF Repeater System 
6.3.1 Recommended 
System Start up Procedure 
•  Verify all RF cables are connected and all unused RF connections terminated with 
50 Ohm terminations. 
•  Verify all Alarm and AC connections are properly made 
•  Connect fiber optic cables.   
•  Apply AC power to system components. 
 
6.4 Caution 
RRU has internal AC power connections that can cause shock if operator is not 
careful.  Always verify the AC Power area is clear of all objects. Do not leave 
objects inside the RRU that can cause dangerous shock hazard. 
 
 
7 Maintenance 
 
This Fiber Optic repeater system does not require scheduled maintenance.  
However, use precautions while installing optical fibers to keep connector surfaces 
clean.  An unclean optical connector surface can damage the internal transceiver 
connector which can degrade system performance and violate Fiber-Span warranty.  
Keep heat dissipating surfaces or vents clean and clear. 
 
8 Company 
Information 
 
Fiber-Span designs and manufactures fiber optic modules and systems used in the 
transmission and distribution of RF and wireless signals. Fiber-Span’s fiber optic 
transmitters, receivers and transceivers are widely used in wireless and RF systems 
worldwide by wireless systems OEM’s, systems integrators and military systems 
designers to capitalize on the inherent advantages of fiber. Fiber has extremely low 
RF attenuation (< 1dB/km), very high bandwidth, immunity to EMI, no signal egress, 
flat broadband delay characteristics plus a cable design that is light weight and 
small size. 
 