ZTE Corporation C806 用户手册

下载
页码 60
Chapter 1 Product Overview
Interface Name
Function
Interface Type/Connector
LC2
Interface between BBU and RRU/RRU
cascading interface
LC optical interface
AISG device interface
8-core aerial socket
Mon
External device interface
37-core aerial socket
DC IN
Power interface
DC interface connector: 4-pin
straight round connector
RXIn
Frequency expansion interface
N connector
RXout
Frequency expansion interface
N connector
RX/TX
Receive/Transmit main set RF cable
interface
50 Ω DIN connector
RX
Receive diversity RF cable interface
50 Ω DIN connector
1.7 Application Scenarios
ZXSDR R8860 supports gantry-mount, wall-mount, pole-mount and simplified—cabinet
integrative installation modes.
The application scenarios are classified into the following situations according to different
installation conditions, power supply requirements and user demands:
l
In the condition of ZXSDR R8860 indoor installation with the DC power cable 10
m outside the equipment room and without Level B and above lightning module
configured in the indoor power output, the indoor DC lightning box is adopted for
power supply and power distribution.
l
When ZXSDR R8860 is installed outdoors, an external DC lightning box is adopted
for power supply and power distribution.
l
A wave trap module is needed in some countries or districts due to the special demand
on the radio network or stations.
Wall-Mount Installation
illustrates the wall-mount installation
1-7
SJ-20100722143906-001|08/30/2010
ZTE Proprietary and Confidential