ZTE Corporation ZXG-OB06 用户手册

下载
页码 117
 
ZXG10 OB06 ZTE  Integrated Outdoor GSM Base Station Technical Manual 
12 
Confidential and Proprietary Information of ZTE CORPORATION 
status and alarm management, software version management, 
device test and external alarm collection. 
ii. DBS 
The whole application layer is designed with the database as a core. 
The database coordinates to assign configuration parameters. It 
also synchronizes data between the active and standby CMMs and 
between the foreground and the background. 
iii. LMU 
It is the local O&M unit, including two parts: foreground agent and 
background operation interface. 
It works with the database synchronization module to complete the 
local parameter configuration, equipment status and alarm 
collection. It also includes operating interface of equipment test to 
implement test functions of the local BTS. 
The system tool part is a series of developer-oriented tools for 
system diagnosis and test to rapidly locate faults. 
FUC 
The FUC software module is located in the TPU of the TRM module. It 
processes the radio signaling over every radio carrier and signaling on the 
BSC interface and manages all channels. Its major functions are as follows: 
1.  It processes and converts GSM signaling protocols, including the layer-
2 protocol LAPD with BSC, the layer-2 protocol HDLC with CMM, the 
layer-2 protocol LAPDm with the Um interface and the layer-3 radio 
resources management protocol of GSM. 
2.  It is responsible for the TDMA multi-frame framing on the Um interface, 
frame number (FN) receiving, frequency hopping calculation and 
management & control over CHP. 
3.  It manages OB06 and loads the FUC software and DSP program. It 
supports packet switching services (GPRS or PS for short).