Karlnet Inc. KS-CPO010124B 用户手册
525 Metro Place North, Suite 100
Dublin, OH 43017
Dublin, OH 43017
KarlNet
Office: 614-822-5275
Fax: 614-822-0024
www.karlnet.com
Fax: 614-822-0024
www.karlnet.com
improve the quality of the link between the two remote nodes. The following
table summarizes the possible results of clicking the Advice button, and what
action is warranted based on the results:
table summarizes the possible results of clicking the Advice button, and what
action is warranted based on the results:
Status Risk
Action
Excellent None
You do not need to perform further
diagnostics.
Good None
Run your radio’s Client Manager
tool (for example, ORiNOCO
Client Manager) and walk
throughout the network
environment. The indicators from
the Site Monitor screens should
enable you to see whether you
could optimize the unit placement.
throughout the network
environment. The indicators from
the Site Monitor screens should
enable you to see whether you
could optimize the unit placement.
You may try to optimize antenna
placement to see whether this will
improve the Link Quality result.
improve the Link Quality result.
Marginal Communication
is
still
possible, but this
situation may affect the
unit's
performance.
situation may affect the
unit's
performance.
View Link Test Details to verify.
The unit may have to retransmit lost
packets.
packets.
Verify the Signal Level indicator. A
low Signal Level indicates the unit
has moved away from the base
station.
has moved away from the base
station.
View Link Test Details to verify the
Noise Level indicator. A high Noise
Level indicates a source of
interference in the signal path
between the unit and the base
station.
Level indicates a source of
interference in the signal path
between the unit and the base
station.
Select another unit to verify if the
base station is functioning properly.
Try to optimize antenna placement
to improve the Signal Level or
move it away from the source of
interference.
move it away from the source of
interference.
18