YURASYS CO. LTD. L1900CDMA20R 用户手册

下载
页码 36
 
Date 
  
2003/05/12 
Doc No. 
YRT-030512-1 
Rev No. 
1.0 
File Name 
Manual_RF_20W.doc 
Page 
33/42 
Report by 
JI Hyo Kim 
Approve by 
 
Document control Manager 
Kong He Hur 
Type of Document 
Technical Document 
Title: 20W RF Repeater System Operating Manual 
 
5.6.4. User Control Values 
 
Figure 16 Window of User Control Values 
< Usage > 
Values in edit boxes can be modified directly, and on/off controls and ALC controls can 
be modified by click the button. After modification, press SET button to write the value 
setting to controller.  If you want close the window without writing the values to controller, 
press CANCEL button or OK button to close the window with writing to controller. 
All values except HPA power and LNA power are saved in EEPROM and can be read 
after next power on. 
 
< Items > 
Repeater ID: ID of repeater. 
Set any value user want as long as 9 digits in decimal. 
Repeater Type: Repeater type for help the user classifying the repeater. 
Any value from 0 to 255 can be written. 
System Version: System version for help user classifying repeater version in same type 
Any value from 0 to 255 can be written. 
Over Temp. : Over temperature alarm limit value. 
YQF-041-13 (Rev.0)                    
 