5.6.8. Gain Table 
 
 
 
< Usage > 
Use this dialog box to set the start dB (the lowest out power table value), Gain Table 
and Analog values for each output power value. 
ALC and over power alarm process will operate with this table value 
The value of disabled edit box is the current analog output value of each direction. 
 
< Items > 
           1. dB: analog: Display the target dBm and the detected analog value. 
2. Display the Current detected output power analog value. 
3. dB: Write the target output power (dBm) 
4. Analog
: Write the detected analog value of each out put power in dBm. 
5. Update  FWD/RVS
: After writing the target dB and Analog, Press this button to     
download the value to control board. 
Change Start: The lowest output power value to make gain table. 
To set the lowest output power value, write dB box with –10 ~ 20 value. 
FWD/RVS can have different lowest output power value. 
Change All Value: To change the analog value. 
YQF-041-13 (Rev.0)                    
 