SGEG N.A. INC. FBTT5003 用户手册

下载
页码 1
User’s Manual 
PM FBT T5 SERIES 
Application and performance specification 
Electronic ballast for T5 14x3, T5 21x3,   
Description 
Active power factor correction.  PF≧0.99 
Low harmonic distortion  . 
THD≦10% 
Low lamp current crest factor.  CF≦1.6 
Warn (Rapid) start. 
Long Life 
De-active lamp protection 
Model Line 
 
Volts 
Lamp 
 
type 
Input 
 
watts 
Normal 
 
Line amps 
Power 
 
factor 
Total 
Harmonic 
distortion 
Crest 
 
factor 
PMFBTT514x3 120V/60Hz  T5 14W 
55W 
0.46A 
0.99
 
<10% <1.6 
PMFBTT521x3 120V/60Hz  T5 21W 
80W 
0.67A 
0.99
 
<10% <1.6 
 
Performance 
 
 
 
 
 
 
 
Safety 
Meets FCC Part 18 (Class A) For EMI 
 
 
 
UL listed 
  Non-consumer 
limits 
Application: 
 
 
 
 
 
 
 
Physical parameters 
Minimum starting temperature  -18℃   Mounting 
length 414mm 
Maximum ambient temperature  40℃ 
    (center 
to 
center) 
Maximum case temperature 
75℃ 
   Overall 
length 
 424mm 
 
 
 
 
 
 
 
 
 
 
Width 
 
 
30mm 
 
 
 
 
 
 
 
 
 
 
Height 
 
 
26mm 
 
This light device has been tested and found to comply with the limits for Consumer RF Lighting 
Device, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation.    This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications.    However, there is no 
guarantee that interference will not occur in a particular installation. 
1.  Use only on 120 volt, 60 hertz. 
2.  Never disassemble or modify - any changes could void the user's authority to operate this device. 
3.  Not for use in totally enclosed fixtures. 
4.  Risk of electric shock - do not use where directly exposed to water. 
5.  This device is not intended for use with emergency exit fixtures or emergency exit lights. 
6.  This product may cause interference to radio equipment and should not be installed near maritime 
safety communications equipment or other critical navigation or communication equipment 
operating between 0.45-30MHz. 
7.  To prevent burns, do not touch the bulb during operation or immediately after switching off. 
8.  Not for use with dimmers, electronic timer or photocell devices or occupancy sensor. 
9.  This device is intended to be professionally installed for Industrial or Commercial use. 
 
Warranty 
Universal lighting technologies warrants to the purchaser that each electronics ballast will be   
marched with the lamp (T5 14x3, T5 21x3) and free from defects in material or workmanship for a 
period of 5 years from date of manufacture when properly installed and under normal condition of use.