1.  The AC wall outlet ground for the indoor POE adapter should be connected to the 
building grounding system as the AN-80i lightning protectors. 
2.  Install a lightning arrestor in series with the Ethernet cable at the point of entry to the 
building. The grounding wire should be connected to the same termination point used 
for the tower or mast. 
3.  Install a lightning arrestor in series with the Ethernet cable as close to the AN-80i as 
practical. The grounding wire should be connected to the same termination point used 
for the tower or mast. 
4.  Provide direct grounding from the AN-80i, the mounting bracket, the antenna, and the 
Ethernet cable surge protection to the same ground bus on the building. Use the 
grounding screws provided for terminating the ground wires. 
 
1.5 FCC 
Notice 
1.  The Model AN-80i is only used for Point to Point application 
2.  The Model AN-80i and it’s antenna must be professionally installed 
3.  FCC & IC RX Exposure Warnings as below: 
 
WARNING:  To satisfy FCC and IC RF exposure requirements for 5.8 GHz 
RF transmitting devices, a separation distance of 3.1 meters or more should be 
maintained between the antenna of this device and persons during device operation. 
To satisfy FCC and IC RF exposure requirements for 5.4 GHz RF transmitting 
devices, a separation distance of 20 centimeters or more should be maintained between 
the antenna of this device and persons during device operation. 
To ensure compliance, operations at closer than these distances is not recommended. 
The antenna used for this transmitter must not be collocated in conjunction with any 
other antenna or transmitter. 
4.  High power radars are allocated as primary users (meaning they have priority) of 
5250-5350 MHz and 5650-5850 MHz and these radars could cause interference 
and/or damage to LE-LAN devices. 
5.  FCC Information to Users @ FCC 15.21 & 15.105: 
This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. 
6. Warning: Changes or modifications not expressly approved by Redline 
Communications could void the user’s authority to operate the equipment. 
7.  Refer to section 6.3: Certified Antennas on page 55) for a list of certified antennas. 
8.  Where DFS is required by regional regulations, this function is permanently enabled 
at the factory and can not be disabled by the installer or end-user.