Redline Communications Inc. AN80IB 用户手册

下载
页码 96
 
 
User
 
 
AN-80i
 
Manual
 
 
70-00072-01-06a 
Proprietary Redline Communications © 2008
 
Page 82 of 96 
June 1, 2008 
If the ping is unsuccessful, there may be problems using that IP address; the IP address 
may be incorrect, or there may be a duplicate address. For correct operation the host 
computer and the AN-80i must be on the same subnet. For example, if the AN-80i is 
using the factory default settings, the host computer could be set for an IP of 
192.168.25.3 and a subnet mask of 255.255.255.0.
 
If the correct IP address of the AN-80i cannot be determined, it is recommended to 
perform the IP recovery procedure. See section 6.2: Procedure to Restore Factory 
Settings on page 80. 
The following table lists some common troubleshooting tips for the web interface. 
Table 35: Diag. - Web Interface Diagnostics 
Symptom Possible 
Problem 
Solution 
Incorrect IP 
address and/or 
Subnet Mask. 
Perform a ping test from the host computer command 
line. 
If the ping test is unsuccessful, then the problem is 
with the IP address. Perform a long reset to apply the 
default address (192.168.25.2) and Subnet Mask 
(255.255.255.0) 
Problems with host 
computer, or AN-
80i. 
If the ping is successful, reset the AN-80i, and/or reset 
the host computer. 
General 
Information 
screen is not 
displayed 
Host PC ARP table 
is incorrectly 
configured 
Run 'arp -d' whenever the AN-80i is swapped. Check 
that the subnet mask for the host PC matches the 
subnet mask of the AN-80i. Check that the host PC's 
address is 192.168.25.n, where 'n' is not equal to 0,2, 
or 255.