3.11 Spectrum 
Sweep 
Click 
Spectrum
 
Sweep
 in the left hand menu to display the Spectrum Sweep configuration 
screen. The spectrum sweep feature is an off-line RF survey tool to detect interference 
and evaluate spectrum availability. Configurable survey parameters include the high and 
low frequency limits, the step size, and the number of samples at each step. The output 
graph displays the maximum (red) and average (blue) RSSI for each step. 
 
Figure 18
: Web - Spectrum Sweep Screen  
Start Frequency (MHz): Enter center frequency of the lowest channel to be scanned. 
See Table 47: Spec. - Regional Identification Codes on page 90. 
End Frequency (MHz): Enter center frequency of the highest channel to be scanned. See 
Table 47: Spec. - Regional Identification Codes on page 90. 
Step (MHz): Enter the frequency step (MHz) to use when scanning from the lowest to 
the highest frequency. The step selection must be a multiple of 2.5 MHz (i.e., 2.5, 5, etc). 
No. of acquisitions: Enter the number of times the frequency will be sampled at each 
step. The recommended range is 10 to 100 samples. When a potentially clear channel is 
identified, reduce the frequency range and step size while increasing the sample size to 
monitor the channel over a longer period.  
Start: Left-click the Start button to begin the scan. 
Performing a Sweep 
The PTP Master or PMP Sector Controller transmitter is automatically disabled during 
the spectrum scan. If the scan is being performed from a PTP Slave or PMP Subscriber, 
the transmitter on the remote AN-80i for this link should be disabled for the duration of 
the test. Use the configuration Test feature (system configuration screen) to remotely 
(over-the-air) disable the remote transmitter for 5 minutes (uncheck   the Radio Enable 
field) and then recover automatically.