6.4 Status 
Codes 
6.4.1  PTP Status Codes 
The PTP status code is displayed in a series of decimal characters representing the status 
of six different alarm conditions. The value '1' indicates the associated condition is active. 
All unused bits are set to zero.  
To determine the status, the decimal number must be converted to binary notation. It is 
recommended to use a scientific calculator that supports binary notation (i.e., Windows 
on-screen calculator). Set the mode for decimal and enter the status code. Change the 
mode to binary and match active bits (1) to the following table. 
For example, if 'RF High Temp. Warning' (2) and ' PHY lock error' (1 0000) were active, 
the status code value would be 34 (binary 100010) (leading zeros are not displayed).
 
Table 36
: Diag. - PTP Status Codes 
Error Type 
Error # 
Decimal* 
Error # 
(binary) 
Description 
Tx Power 
 
1 Power output is less than 10 dBm. This message 
may appear before the RF link is established. 
RF High 
Temp. 
Warning 
10 The transceiver internal temperature rose above 
185F / 85C. The transceiver will shut down for 30 
seconds to allow cooling. 
RF PLL Lock 
Error 
16 
1 0000 The PLL (Phase Locked Loop) section within the 
AN-80i experienced an error. Reset the AN-80i. 
PHY lock 
error 
32 
10 0000 The PLL (Phase Locked Loop) section within the 
AN-80i experienced an error. Reset the AN-80i. 
80 MHz PLL 
lock error 
64 
100 0000 The PLL (Phase Locked Loop) section within the 
AN-80i experienced an error. Reset the AN-80i. 
Firmware 
Configuration 
Error 
128 
1000 0000 Error detected in the AN-80i configuration file. 
*Displayed decimal value if this is the only active error condition.