IP Address: Enter the IP address for this AN-80i. The IP address is routable through the 
Ethernet port and over the wireless interface. 
IP Subnet Mask: Enter the IP subnet mask. 
Default Gateway Address: Enter the IP address of the default gateway or router on the 
Ethernet segment connected to the AN-80i Ethernet port. 
Flow Control Enable: Check this box 
 to enable flow control functions (802.3x) on the 
AN-80i  Ethernet  port.  Enabling  this  feature  allows  the  AN-80i  to  request  Ethernet 
devices to pause transmissions during busy periods. 
Prioritized Low Latency Mode Enable: Check this box 
 to enable priority handling of 
802.1p  tagged  traffic.  When  enabled,  this  ensures  prioritized  traffic  is  transmitted  with 
the lowest achievable latency, even under conditions of high IP data traffic loading. 
Table 9: Web - 802.1p Priority Settings 
Priority 
Setting 
Highest 
6, 7 
 
4, 5 
 
0, 3, no tag 
Lowest 
1, 2 
 
SNTP  Enable:  Check  this  box 
  to  enable  the  SNTP  protocol  support.  This  feature 
allows AN-80i systems to time-stamp log messages using a network time server. When 
enabled, you must enter the network address of the SNTP server in the SNTP Server IP 
Address field.  
SNTP  Server  IP  Address:  Enter  the  network  address  of  the  SNTP  server.  Valid  only 
when the SNTP Enable field is checked. 
Polling Interval: Enter the SNTP polling interval (hours). 
Time Zone (GMT): Enter the hours offset from GMT for this time zone. Valid only when 
the SNTP Enable field is checked. 
Syslog  Enable:  Check  this  box 
  to  enable  the  Syslog  protocol  support. This feature 
allows  AN-80i  log  messages  to  be  saved  in  a  central  repository.  When  enabled,  you 
must  enter  the  network  address  of  the  Syslog  server  in  the  Syslog  Server  IP  Address 
field. 
Syslog Server IP Address: Enter the network address of the Syslog server. Valid only 
when the Syslog Enable field is checked. 
Ethernet Mode: Select the operating mode of the Ethernet port. 
Auto - Auto-negotiate the speed connection speed. 
10 - Operate at 10Base-T only. 
100 - Operate at 100Base-T only. 
HD - Operate at half-duplex only. 
FD - Operate in full duplex only. 
Important:  The  auto-negotiate  feature  does  not  detect  the  speed  and  duplex  of 
manually  set  Ethernet  equipment.  The  auto-negotiate  feature  works  correctly  only 
when both communicating Ethernet devices are configured for auto-negotiate. Duplex 
mismatches may result in an unexpected loss of communications. 
It is recommended to manually configure Ethernet devices to 100Base-T / full duplex.