If the ping is unsuccessful, there may be problems using that IP address; the IP address 
may  be  incorrect,  or  there  may  be  a  duplicate  address.  For  correct  operation  the  host 
computer  and  the  AN-80i  must  be  on  the  same  subnet.  For  example,  if  the  AN-80i  is 
using  the  factory  default  settings,  the  host  computer  could  be  set  for  an  IP  of 
192.168.25.3 and a subnet mask of 255.255.255.0. 
If  the  correct  IP  address  of  the  AN-80i  cannot  be  determined,  it  is  recommended  to 
perform  the  IP  recovery  procedure.  See  section  6.2:  Procedure  to  Restore  Factory 
Settings 
on page 85. 
The following table lists some common troubleshooting tips for the web interface. 
Table 45: Diag. - Web Interface Diagnostics 
Symptom 
Possible Problem 
Solution 
General 
Information 
screen is not 
displayed 
Incorrect IP 
address and/or 
Subnet Mask. 
Perform a ping test from the host computer command 
line. 
If the ping test is unsuccessful, then the problem is 
with the IP address. Perform a long reset to apply the 
default address (192.168.25.2) and Subnet Mask 
(255.255.255.0) 
Problems with host 
computer, or AN-
80i. 
If the ping is successful, reset the AN-80i, and/or reset 
the host computer. 
Host PC ARP table 
is incorrectly 
configured 
Run 'arp -d' whenever the AN-80i is swapped. Check 
that the subnet mask for the host PC matches the 
subnet mask of the AN-80i. Check that the host PC's 
address is 192.168.25.n, where 'n' is not equal to 0,2, 
or 255.