Payloads can be classified by multiple parameters including L2 MAC source and 
destination address, 802.1p/Q settings, DSCP and TOS bits, L3 IP source and 
destination address, and L4 TCP/UDP port number. Ingress classification for payload 
admission into the Service Flow architecture is performed at the subscriber/MS for uplink 
forwarding, and at the ASN-GW for downlink forwarding. 
Requests for specific QoS settings can originate from the subscriber, a host connected 
to the subscriber, or a source outside the WiMAX network (e.g., an intermediate server). 