5.2.1 No Redundancy
This deployment scenario provides maximum economy without redundancy. In this
configuration, failure of the TCM or PWM module will cause the system to be
unavailable. Failure of a BBM will result in a loss of service for the affected sector.
Failure of a sector radio will revert to SISO for the affected sector or a loss of the sector
(based on the type of failure).
configuration, failure of the TCM or PWM module will cause the system to be
unavailable. Failure of a BBM will result in a loss of service for the affected sector.
Failure of a sector radio will revert to SISO for the affected sector or a loss of the sector
(based on the type of failure).
Table 23: 3-Sector with No Redundancy
Module
Quantity
Failure Mode
System Action
PWM
1
Failure of PWM
System unavailable
TCM
1
Failure of TCM
System unavailable
BBM
1
Failure of BBM
Sector unavailable
RRH 3
Failure of one RF PCB
Sector reverts to SISO
Failure of digital PCB
Sector unavailable