Budderfly LLC R0710021 用户手册

下载
页码 3
 
 
 
Part No R0710021 
Description: 
Installing a Budderfly adapter transforms your building’s existing wiring into the “Budderfly Open Network” and allows the 
adapter to monitor energy consumption and communicate the data to a facility controller. 
Budderfly adaptors use the existing power line for communication and thus require no re‐wiring. 
Using our Budderfly software, you can visualize consumption data and manage each individual adapter. 
The Budderfly Dual Band Outlet is a component of Budderfly system and designed to work with all other Budderfly devices. 
It is a plug‐and‐play replacement for your existing Outlet. Once installed, The Budderfly outlets also act as repeaters to 
extend the range of the network and increase efficiency. 
 
  Installation: 
   The Budderfly Dual Band Outlet may be used in new installations or to replace an existing Outlet. The wiring schematic will be as per below:
 
1.  At the circuit breaker or fuse panel, disconnect the power for all of the circuits 
in the switch junction box.  
2.  Double Check that the power is OFF to the Outlet by trying to turn on a 
device connected to the plug before continuing. 
3.  Remove the wall plate from the plug you are replacing. Then, unscrew the 
outlet itself and pull it out from the junction box. 
4.  Disconnect the wires from the outlet you are replacing. 
5.  Follow the Wiring information provided below and connect the wires as 
follows: 
‐  Connect the GROUND wire (usually Bare Copper or Green) to the Ground wire 
of Budderfly Dual Band Outlet (Yellow & Green). 
‐  Connect the LINE wire (usually Black) that comes from the electrical service 
panel to the HOT wire of Budderfly Dual Band Outlet (Black). 
‐  Connect the NEUTRAL wire (usually White) to the Neutral wire of Budderfly 
Dual Band Outlet (White). 
6.  After you have connected all of the wires, ensure that all of the wire 
connectors are firmly attached and that there is no exposed copper except for 
the GROUND wire. 
7.  Gently place Budderfly Dual Band Outlet into the junction box. Then, screw 
the Outlet into place. 
8.  Reinstall the wall plate 
9.  Enable power to the Outlet from the circuit breaker or fuse panel 
10. Add the device address to the Budderfly software. 
WARNING: If you are not sure about any part of the above instructions, consult a 
qualified electrician. 
 WARNING –ELECTRICAL SHOCK HAZARD 
• 
The Budderfly Dual Band Outlet is intended for installation in accordance with the 
National Electric Code and local regulations in the United States.
 
• 
If you are not knowledgeable or comfortable with electrical circuitry, you should have a 
qualified electrician install the Budderfly Dual Band Outlet for you.
  
 Warning 
• 
Install the Budderfly Dual Band Outlets indoor only. 
• 
Never use the Budderly Outlets to power medical and/or life support equipment. 
• 
The equipment plugged into this Budderfly Dual Band Outlet must not exceed 
2400W at 120VAC.
WARNING –ELECTRICAL SHOCK HAZARD 
• 
Turn OFF the power to the branch circuit for the Outlet at the 
service panel. 
• 
All wiring connections must be made with the POWER OFF to 
avoid personal injury and/or damage to the Outlet. 
 Wiring Information 
• 
Important: Budderfly Outlet is rated for and intended to only 
be used with copper wire. 
• 
Use 12 AWG or larger wires suitable for 80
o.
 
• 
Remove 3/4" (1.9 cm) of insulation from each wire. 
Connect as follows: Twist strands of each end tightly together. Hold 
bare ends of wires together and push firmly into wire Nut. Screw Nut 
clockwise making sure that no bare conductor shows below the 
connector