Single Pole (One location) or 3-Way (Multi-location)
Electronic Low-Voltage Dimmer (Lighted)
Cat. No. RZEØ6-1L, 600W
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS
:
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
•  Use with electronic low-voltage transformers only. Do Not use to control a magnetic low-voltage transformer. Use a Leviton magnetic low-voltage dimmer to control magnetic
  low-voltage transformers.
•  This dimmer provides protection from overheating. An excessive load applied to the dimmer will cause the dimmer to overheat. The excess load must be removed to resume proper 
operation.
•  Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes or Vizia™ RF controllers for multi-location dimming.
•  Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 Vizia™ coordinating remotes without LEDs or Vizia™ RF controllers. 
WARNINGS AND CAUTIONS
:
•  Lighting fixture and dimmer must be grounded.
•  This dimmer must be installed in a wall box with a neutral connection.
•  Consult fixture manufacturer to determine if their solid state transformers can be dimmed.
•  Total minimum load must exceed 40W.
•  Dimmer may feel warm to the touch during normal operation.
•  Recommended minimum wall box depth is 2-1/2".
•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
IMPORTANT : For 3-Way applications, note that one of the screw 
terminals from the old switch being removed will usually be a different 
color (Black) or labeled Common. Tag that wire with electrical tape and 
identify as the common (Line or Load) in both the dimmer wall box and 
remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
DI-000-RZE06-00A-X0
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No.
VZEØ6
Single
600W
Two Devices
500W
More than 
2 Devices
400W
 Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver 
Electrical Tape
Pliers 
 
 
Pencil
Cutters 
 
 
Ruler
When installing more than one dimmer in the same location, the 
side sections of the mounting strap must be removed. Use pliers to 
carefully bend side sections back and forth until they break off. The 
side sections dissipate heat, so removing them sometimes requires a 
derating of the dimmer’s capacity 
(refer to chart).
Remove all 
inner side 
sections
Bend back 
and forth to 
remove side 
section
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
Cut 
(if necessary)
5/8" 
(1.6 cm)
Strip Gage (measure 
bare wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that 
the ends of the wires from the wall box are 
straight (cut if 
necessary). Remove insulation from each wire in the wall 
box as shown:
•  For Single-Pole Application, go to Step 4a.
•  For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.
Dimmer
Insulating
Label
Black
Primary
Side
Electronic
Low-Voltage
Transformer
Hot (Black)
Black
Line
120VAC, 60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
•  Green or bare copper wire in wall box to Green dimmer lead.
•  Line Hot wall box wire to Black dimmer lead.
•  Load wall box wire to Red dimmer lead.
•  Line Neutral wall box wire to White dimmer lead.
•  Yellow/Red wire should have Red insulation label affixed. 
 
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, 
use electrical tape to cover.
• 
Proceed to Step 5.
Hot (Black)
Neutral (White)
Dimmer
Coordinating Remote (no LEDs)
YL/RD
Yellow/Red
RD
White
Red
Black
Black
BK
WH
White
Line 
120VAC, 60Hz
Green
Ground
Green
Ground
Electronic
Low-Voltage
Transformer
Primary
Side
(unused)
(unused)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: The dimmer must be installed in a wall box that has a Line 
Hot connection.
NOTE: Maximum wire length from dimmer to all installed remotes 
cannot exceed 300 ft (90 m).
•  Green or bare copper wire in wall box to Green dimmer lead.
•  Line Hot (common) wall box wire identified (tagged) when 
removing old switch to Black dimmer lead.
•  First Traveler wall box wire to Red dimmer lead 
(note wire color).
•  Remove Red insulating label from Yellow/Red dimmer lead.
•  Second Traveler wall box wire to Yellow/Red dimmer lead 
(note 
wire color). This traveler from the dimmer must go to the terminal 
screw on the remote marked "YL/RD".
•  Line Neutral wall box wire to White dimmer lead.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are unused.  
Tighten both screws.
NOTE: Maximum wire length from dimmer to last remote is 
300 ft (90 m).
•  Green or bare copper wire in wall box to Green terminal screw.
•  Load wall box wire identified (tagged) when removing old switch 
to First Traveler 
(note color as above).
•  Second Traveler wall box wire 
(note color as above) to terminal 
screw marked "YL/RD". This traveler from the remote must go to 
the Yellow/Red dimmer lead.
•  Remove White insulating label from terminal screw marked "WH". 
•  Line Neutral wall box wire to terminal screw marked "WH".
• 
Proceed to Step 5.
INSTALLING YOUR DIMMER
NOTE: Use check boxes           when Steps are completed.
2
4
3
1
2
4
1
5
3
Single Pole
1.
 Line (Hot)
2. Neutral
3. Ground
4. Load 
3-Way
1.
 Line or Load (see important instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color. NOTE: For 
matching remote w/LEDs installation, the 
First Traveler becomes Line Hot.
MULTI-DEVICE APPLICATION
NOTE: You only need to remove side sections if installing with other 
dimmers or if it does not fit in wall box – not when installing with 
mechanical switches.
If installing Dimmer in a single device application, proceed with the 
INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:
 Installing Dimmer by itself or with other devices:
Changing the color of your Dimmer:
Your Dimmer includes three color options. The Dimmer ships with the 
White frame attached. To change color of frame, proceed as follows:
Push in side at 
tab to release
Line up tabs and 
press in side to attach
WARNING: 
TO AVOID FIRE SHOCK OR DEATH; TURN 
OFF POWER at circuit breaker or fuse and test that power 
is off before wiring!
 
Step 1
Identifying your wiring application 
(most common):
NOTE: If the wiring in your wall box does not resemble any 
of these configurations, consult a qualified electrician.
 
Step 2
 
Step 3
Single Pole Wiring Application:
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
4
Black
White
Green
Red
Yellow/Red
2
3
 
Step 4a
 
Step 4a cont'd
Coordinating Remote
Dimmer
BK
WH
YL/RD RD
5
1
4
5
Green
Yellow/
Red
Red
Black
White
2
1
4
3
2
3
3-Way Wiring with Coordinating Dimming or 
Switching Remote (no LEDs) Application:
(Coordinating Dimming Remote depicted)
 
Step 4b
 
Step 4b cont'd
Compatible with
enabled products!
TM