Advanced Control Technologies Inc. 0763-03 用户手册

下载
页码 5
LSM-20 Instructions 
P/D 112609
LSM-20
by EVOLVE GUEST CONTROLS
3
SteP 2.  the LSM-20 must be in its permanently installed location. Tap either the top or bottom of the LSM-20 once. 
STEP 3.  You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network. 
note: If you have trouble adding the LSM-20 to a group it may be that the Home ID and Node ID were not cleared from it after testing. 
You must first “RESET UNIT” with your controller to remove it from the network. If using the IR-100, select “SETUP” and scroll to “RESET 
UNIT” 
Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed from a 
group, it functions as a repeater (only).  “RESET UNIT” removes it completely from the network.   
BaSic oPeRation
 (Local Control)
The switch paddle on the LSM-20 allows the user to:
• Turn the attached load on or off.
• Include or exclude the module from the Evolve system 
• Control other Evolve enabled devices.
Also, when a controller prompts you to “Send Node ID” or to “Press button on Unit”, quickly tap the switch on or off once to satisfy those 
instructions. 
• Tapping top of switch turns the load attached ON.
• Tapping bottom of switch turns the load attached OFF.
• Pressing and holding switch does not effect the load attached to the LSM-20, but will allow dimming and brightening of Evolve dim-
mers if associated (see below for details).
LED indication
The LED on the LSM-20 will turn on when the load attached is ON. The LED can be user configured however to turn ON when the load attached 
is OFF, if so desired, to act as a night light. See ADVANCED OPERATION section.  
The LSM-20 will flicker its LED when it is transmitting to any of its 2 groups. This can be changed if desired. See ADVANCED OPERATION 
section.  
Auxiliary Switch
The LSM-20 supports the AS101 auxiliary switch to provide 3-way or 4-way operation. 
Remote Control
The LSM-20 will respond to bASIC and bINARY commands that are part of the Evolve system. Refer to your controller’s instructions as to 
whether your controller can transmit those commands.
Internal circuit protection
The LSM-20 internal circuitry is protected by an internal fuse. This internal fuse is factory serviceable only. Check your home circuit breakers 
before concluding that the product must be returned to manufacturer for repair at a nominal charge.
AdVANCEd OPErATiON
All On/All Off
The LSM-20 supports the ALL ON/ ALL OFF commands.
The LSM-20 can be set to respond to ALL ON and ALL OFF commands four different ways.
Refer to your controller for information on how to set the LSM-20 to operate in the manner you desire. Some controllers may be only able to 
set certain settings of ALL ON/ALL OFF response.
The four different ways the LSM-20 can be setup to respond to ALL ON and ALL OFF commands are:
1. LSM-20 will not respond to aLL on or the aLL oFF command.
2. LSM-20 will respond to aLL oFF command but will not respond to aLL on command.
3. LSM-20 will respond to ALL ON command but will not respond to ALL OFF command.
4. LSM-20 will respond to ALL ON and the ALL OFF command.
Association