Test Item 
Test Condition 
Test Standard 
Temperature shock   
Low temperature:  –40°C±2°C 
High temperature: 85°C±2°C 
Changeover time: < 30s   
Test duration: 1 hour 
Repetition times: 100 
IEC 68-2-14 Na 
Damp heat cyclic 
High temperature: 55°C±2°C 
Low temperature: 25°C±2°C 
Humidity: 95% 
Repetition times: 4 
Test duration: 12 hours + 12 hours 
IEC 68-2-30 Db 
Low-temperature 
operation 
Temperature:  –30°C±2°C 
Test period: 24 hours 
IEC 68-2-1 Ab   
High-temperature 
operation 
Temperature: 75°C±2°C 
Test period: 24 hours 
IEC 68-2-2 Bb 
Low-temperature 
storage 
Temperature: –60°C±2°C 
Test period: 24 hours 
IEC 68-2-1 Ab 
High-temperature 
storage 
Temperature: 90°C±2°C 
Test period: 24 hours 
IEC 68-2-2 Bb 
Salt spray test 
Temperature: 35°C 
Density of the NaCl solution: 5%±1% 
Spraying duration: 48 hours 
Duration of exposing the module to the 
temperature of 35 ºC: 16 hours 
IEC 68-2-11 
 
3.7 ESD Features 
3.7.1 Overview 
When the UM01-HW UMTS module is in use, the ESD protection should be considered. The 
ESD performance of the UM01-HW UMTS module has been tested according to the 
EN61000-4-2 standard. Table 3-9 shows the test results. 
Table 3-9 ESD performance 
Interface 
Air Discharge 
Contact Discharge 
USIM card interface 
±8K V 
±4K V 
USB interface 
±8K V 
±4K V