Without having the serial numbers in the Call Book, a Slave may establish communications with different 
Masters, though not at the same time.  This is very useful in mobile MultiPoint applications. 
(8)
 
M
ULTI
M
ASTER 
S
YNCH
 
MultiMaster Synch is reserved for applications, in both Point-to-Point and MultiPoint modes, with 
concentrations of Master units where it is necessary to reduce interference between the Masters.  Please 
contact FreeWave Technologies for more information.  
(9)
 
1
 
PPS
 
E
NABLE
/D
ELAY
 
The 1 PPS Enable/Delay option allows the radio network to propagate a 1PPS signal from the Master to 
all Slaves in a MultiPoint network. When this parameter is enabled a properly generated pulse applied on 
the DTR line of the Master will provide a 1 PPS pulse on the CD line of any Slave in the network.  To use 
the 1 PPS Enable/Delay feature the steps outlined below must be followed: 
1PPS Enable/Delay Setup: 
1. 
The 1 PPS Enable/Delay parameter must be set to 0 in the Master. 
2. 
The Master must have a 1 PPS pulse on the DTR pin. 
3. 
The 1 PPS Enable/Delay parameter on the Slaves must be enabled. Slaves are calibrated at the 
factory. 
Calibrating a Slave in 1PPS Enable/Delay mode 
1.  Trigger an oscilloscope on the 1 PPS pulse on the DTR line of the Master. 
2.  Monitor the CD line of the Slave. 
3.  If the timing on the Slave differs from the Master it may be adjusted via the value in the Slave's 1 
PPS Enable/Delay parameter.  The difference in time between each incremental integer value is 
542.534nS.  Changing the parameter to higher values decreases the Slave time delay and 
changing the parameter to lower values increases the time delay.  
When properly calibrated the CD line of a Slave radio will output a pulse that goes high for about 2mS in 
synch with the 1 PPS pulse on the Master radio.  The output on the Slave will occur within 20 
microseconds of the input to the Master. 
Note:   When 1 PPS is enabled, the Master must have a 1 PPS pulse on its DTR pin, otherwise the RF 
network will not function. 
(A)
 
S
LAVE
/R
EPEATER
 
Repeaters are not available in the FreeWave 760 MHz Data Transceivers. 
(B)
 
D
IAGNOSTICS
 
This option provides diagnostics data to be viewed at the Master in parallel with application data.  The 
diagnostic program MUST be run from the Master transceiver.  Diagnostics requires the following: 
1. 
Diagnostics set to (1 to 128) in the Master. 
2. 
A second computer or serial connection to run the diagnostics software. 
3. 
A diagnostics cable. (Available from FreeWave Technologies.) 
4. 
Diagnostics software. (Available on the User Manual and System Tools CD.) 
For more information on Diagnostics, please contact FreeWave Technical Support at (303) 381-9200.