10
The RMP60 probe can be in one of three modes:
1. Stand-by mode - The RMP60 is waiting for
a switch-on signal .
2. Operating mode - Activated by one of the
switch on methods described on this page.
In this mode and the RMP60 is now ready
for use.
3. Configuration mode - The trigger-logic
configuration method allows a number of
RMP60 set-up options to be configured by
triggering the RMP60, including the switch-off
options described on
 
page 25.
Modes of operation
Modes of operation
                   RMP60 switch-on
RMP60 power on/off
Switch-on options are configurable
 - see page 13.
Three switching methods can be used.
1.
Radio start
Radio switch-on is commanded by
M code.
2.
Spin start
Spin at 650 rev/min for 1 sec minimum
(maximum 6 sec)
3.
Shank switch
Note:
RMP60 will be turned on after 1 sec in all
modes.