Setup is done by using the RMP60 trigger logic
and powering on the RMI at a particular time
during the process.
Trigger logic is a method that allows user
configuration of the options available in the
RMP60. Trigger logic uses a sequence of
RMP60 triggering and battery insertion
followed by further RMP60 triggering.
This leads the user through a series of choices
allowing selection of the required options.
Reviewing of choices made can be made by
battery insertion alone. See pages 12 and 13 for
full details of reviewing probe settings and
configuration using trigger logic.
1.
Use trigger logic to set RMP60 turn on/ off
modes as desired.
2.
Use trigger logic to access RMP60
acquisition mode (light blue flashes, 2 short
1 long).
System setup/establishing RMP60-RMI partnership.
RMP60-RMI partnership
3.
Power on the RMI.
4.
Wait until RMI signal led flashes green.
5.
Trigger the probe (min 0.1 sec max 2 sec)
RMP60 will flash 2 x turquoise short,
followed by 1 red long and repeat until
acquistion occurs.
6.
RMI pattern will change to red & yellow
flashing when it acquires the RMP.
7.
Allow ~10 seconds for both RMP60 and
RMI to timeout all RMP60 LEDs off and RMI
signal LED off. The system is then ready for
use.
Warning
When holding the RMP60 do NOT wrap
a hand, or anything else, around the
glass window.
!
continued on next page